Measured from finish floor to clear opening.
Basement egress window requirements mn.
From the east coast s hurricane laura to iowa s devastating derecho.
Licensed bonded and insured leave your egress project in the hardworking hands of our experienced crew.
If you have a finished basement or plan on adding a living space to any part of your home or even if you re just upgrading your window fixtures you ll need to abide by these regulations.
All of these rooms are required to have a means of egress.
Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches 1118 mm measured from the finished floor to the bottom of the clear opening.
The minimum egress window opening height is 24 high.
Basement egress window requirements.
The bottom of the egress window opening can t exceed 44 from the finished floor.
Windows in rooms used for foster care or day care licensed or registered by the state of minnesota shall comply with the provisions of section r310 2 5 or all of the following conditions whichever is more restrictive.
In addition the egress window requirements for basements specifies that they be at least 36 inches in height and width with a fully functioning opening.
When the sill height of an egress window is located below grade common for egress windows provided for a basement a window well must be provided.
Additionally egress windows can only reach a maximum of 44 from the ground.
The minimum opening area of the egress window is 5 7 square feet.
Where basements contain one or more sleeping rooms emergency egress and rescue openings shall be required in each sleeping room.
Egress window well code requirements.
Minimum of 20 inches in clear opening width.
Learn more about the state s masking requirements and minnesota s response to covid 19.
The egress door shall be side hinged and shall provide a minimum clear width of 32 inches 813 mm when measured between the face of the door and the stop with the door open 90 degrees 1 57 rad.
It must be at least 5 7 square feet that is at least 20 inches wide by 24 inches high with an opening no higher than 44 inches from the floor.
The area of a window well shall not be less than 9 square feet with a horizontal length width of no less than 36 inches.
Egress window guy is your egress window and well installation and repair specialists serving minnesota and western wisconsin with integrity and professionalism since 2001.
Basement bedroom sleeping room requirements section r310 all sleeping rooms shall have at least one egress window see illustration meeting all these requirements.